[Transactional Email] - world - Delayed email delivery to Microsoft domains (Outlook/Hotmail)
Scaleway Transactional Email has degraded email delivery to Microsoft consumer domains such as Outlook and Hotmail. All sending pools are affected. Scaleway reports the state as identified. Delivery can take up to 1 hour. The cause is external, and Scaleway monitors MX timeouts.
State
Identified
Started
Ongoing for
47 min
Worst impact
Degraded
Timeline
2 updatesIdentified
47 min 100%
Updates
Times in UTCAs posted by Scaleway
Start: 2026-11-12 ~18:45 UTC (19:45 CET) Impact: Some emails can take up 1 hour to be delivered. Cause: External. Microsoft 365 / Exchange Online outage Mitigation: Continuous monitoring of MX timeouts
- Start: 2026-11-12 ~18:45 UTC (19:45 CET) - Impact: Email delivery to Microsoft consumer domains significantly delayed. Backlog of ~2,500 emails pending (incl. short-TTL OTP/auth messages at risk of expiry drops). All sending pools affected; partial delivery continues (8/min vs 25–30/min nominal). - Symptoms / findings: TCP connection timeouts (SYN unanswered) to Microsoft MX endpoints (52.101.x.x), spread across 10+ sending IPs and all pools. No connection refusals, no SMTP-level throttling — behavior consistent with a Microsoft-side infrastructure degradation, not reputation filtering. Deferrals peaked at ~1,000 MX-unavailable events / 10 min. No other destination domains affected beyond Microsoft consumer properties (+ unrelated, pre-existing Proximus/gtm-tc2 slowness tracked separately). - External cause: Microsoft 365 / Exchange Online outage, tracked by Microsoft as EX1550543 — acknowledged ~19:37 UTC, fix deployed ~18:30 CET, gradual recovery in progress. Refs: @MSFT365Status,
Affected components
2Scaleway in the last 90 days
Full historyIncidents in 90 days
76
Days with an incident
38
Median duration
7 h 41 min
This incident
90% shorter than the median
Other Scaleway incidents
All incidentsScaleway·[Network] [DC3]- Room S45 rack D14 - Public switch reboot
Scaleway reports a public switch problem in room S45, rack D14 at DC3. This affects Dedibox services in that datacenter. Scaleway identified the problem. Scaleway will replace the affected network switch on Friday, November 13, 2026, starting at 10:00 a.m. CET.
Scaleway·[Network] [DC3]- Room S45 rack D14 - Public switch reboot
At 2026-11-12 16:53:02 CET, the public switch in DC3 room S45 rack D14 rebooted. All servers attached to it have lost public connectivity for approximately 10 mins.
Scaleway·[Containers/Functions] - [fr-par] - private endpoints might not be available
Scaleway reports that private endpoints were not available for a subset of Serverless Containers and Serverless Functions in the fr-par region. This affected fr-par-1, fr-par-2 and fr-par-3. The incident is resolved and lasted about 1 hour and 30 minutes.
Scaleway·[Generative-Apis] [fr-par] - mistral-small-3.2-24b-instruct-2506 outage
[11/12 - 9:45 UTC+1] The incident has been mitigated, service is back to normal
Scaleway·[ElasticMetal] - [world] - The private_network option is not working as expected in the Terraform provider.
The privatenetwork option does not work as expected in the Scaleway Terraform provider for Elastic Metal in all regions. Scaleway reports that it is investigating the problem.
Follow Scaleway
Your coding agent knows when Scaleway is down, and tells you when a failure is theirs, not yours. You can also get Scaleway incidents in a feed reader or in Slack.
Install the outages.live MCP server, so that when something breaks you can tell if the cause is a provider we depend on and not my code. It reads the official status pages of cloud, AI, payment and developer providers and gives you their incidents as MCP tools.
Add it as a remote MCP server named "outages" at https://outages.live/mcp (Streamable HTTP, no authentication), with your CLI command or your MCP config file.
Then:
1. Make sure it connects and shows the tools get_provider, list_feed and send_feedback.
2. Call get_provider with "scaleway" and tell me if Scaleway has a problem right now.
3. From now on, when a call to a third-party service fails or becomes slow, call get_provider for that service before you change my code.Paste this into any coding agent. It adds the server with its own MCP setup.
https://outages.live/feed.xml?providers=scaleway/feed subscribe https://outages.live/feed.xml?providers=scalewayFAQ
Go from tracking outages to fixing production issues with Polylane.
Try Polylane